SPECO TECHNOLOGIES CVC-927PTZ DOME CAMERA Instruction Manual Please read this manual thoroughly before use and ke
Chapter 2 — Installation and Configuration 2.1 Package Contents The package contains the following. Fastrax II E (Dome Camera) ………………………1 Bubb
2.2 Basic Configuration of Fastrax II E Dome Camera System. 3~45~81~21~4ALARM OUTPUTUP TO 4ALARM OUTPUT ALARM OUTPUTALARM INPUTHALF DUPLEX MODE : RX+
The dome camera must be installed by qualified service personnel in accordance with all local and federal electrical and building codes. The system s
Figure 7- Termination Diagram 6
2.4 Setting Dome Camera Address (ID) To prevent damage, each dome camera must have a unique address (ID). When installing multiple dome cameras usin
2.5 Setting Dome Camera Protocol If a dome camera is to be installed with a Fastrax keyboard controller, select F2 protocol. Consult service perso
2.6 Connections • Connecting to the RS485/ 422 The dome camera can be controlled remotely by an external device or control system, such as a control
OSD Position RAM TEST CHECK NO. : OK! CHECK AAAA : OK! CHECK 5555 : OK! FASTRAX II E Vx.xxx
Chapter 3 — Program and Operation 3.1 Dome Camera Selection Before you program or operate a dome camera, you must select the dome camera by pressin
3.3 How to control the On-Screen Menu Utility Action Function MENU Call the On-screen menu utility Joystick left or right Go into the sub-menu item
Warnings and Cautions TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE. DO NOT INSERT ANY METALLIC OBJ
1. Press the SCAN key to enter Auto Scan menu directly. Or press the MENU key to display the main menu on the monitor. Scroll to Auto Scan and push
3.5 Preset (Second Item of the Main menu / Shortcut: PRST) If you need to view specific places routinely, you should program presets. A preset is
5. After aiming the camera (view direction and lens control), release CTRL/PGM. Then twist the Joystick handle or Press Tele or Wide Key to store the
Tour2 executes as follows: Preset3 Î Preset4 Î Preset7 Î Preset5 Î Preset1 … Repeat (Tour4 is still valid if called directly from Tour2.) TOUR
through the alphanumeric characters. Push the handle to the right or left to select the next or previous digit. 9. Select Save and Exit by pushing th
7. Pressing ESC will not save your information and exits to the previous mode. Press the HOME key at any programmed position to delete that programm
3.10 Area Title (Sixth Item of Main menu) Enter a specific name on programmed angle between START and END. For the screen below, when the camera
3.11 Privacy Zone (Seventh Item of Main menu) Hide up to 8 unwanted views in a camera. PRIVACY ZONE SETUP NO TITLE METHOD 01 xx
3.12 Camera (Eighth Item of Main menu) – HID2404SxExxx MODEL NOTE: The menu features will vary depending on the camera module installed in your dom
• WB (white balance) CONTROL MODE MANUAL / AUTO / INDOOR / OUTDOOR / ONE PUSH / ATW RGAIN 0 ~ 255 BGAIN 0 ~ 255
FCC COMPLIANCE STATEMENT THIS CLASS A DIGITAL APPARATUS COMPLIES WITH CANADIAN ICES-003. CET APPAREIL NUMÉRIQUE DE LA CLASSE A EST CONFORME À LA
• LINE LOCK CONTROL MODE INTERNAL / EXTERNAL Adjusts phase of picture with other PHASE 0~255 ca
3.13 Camera (Eighth Item of Main menu) – HID2404HCExxx MODEL NOTE: The menu features will vary depending on the camera module installed in your dom
• WB (white balance) CONTROL MODE MANUAL / AUTO RGAIN 0 ~ 255 BGAIN 0 ~ 255 Use the AUTO mode for normal use.
• LINE LOCK CONTROL MODE INTERNAL / EXTERNAL Adjusts phase of picture with other PHASE 0~255 ca
3.14 Dome Setup (Ninth Item of Main menu) CONFIGURATION MENU HOME FUNCTION SETUP OSD DISPLAY VIEW ANGLE SETUP INITIALIZE DATA ORIGIN OFFSET D
• OSD DISPLAY CAMERA TITLE : 8 CHARACTER CAN BE SET VIEW DIRECTION : ON / OFF DOME OSD DISPLAY : ON / OFF AREA DISPLAY :
• PANNING RANGE When the dome camera is installed near a wall, panning range can be limited by user. • FLIP Allows the dome camera to au
Erase all stored data from the Flash-ROM of the selected dome camera. You will be asked to enter Yes or No. If you intend to erase all data then pres
Appendix A — Specifications Camera(HID2404SLExxx) Image Sensor 1/4" Super HAD Color CCD (Sony) Picture elements NTSC : 768x494 Approx. 3
View angle Approx. 45° (WIDE end) to 2° (TELE end) Minimum Illumination 2.5 lux(F1.4,normal shutter speed) 0.2 lux (F1.4,1/4S(NTSC) OR 1/3S(PAL) 0.01
IMPORTANT SAFEGUARDS 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do
General Certification CE EMC, FCC CLASS A, UL Electrical Input Voltage 18 to 30 VAC; 24 VAC nominal, built-in power-line surge Power Requiremen
Appendix B — Troubleshooting If problems occur, verify the installation of the camera with the instructions in this manual and with other operating
Appendix C — Glossary Alarm Actions The assigned responses for the dome camera when inputs change from normal to abnormal states. The dome may run a
IR Mode A feature of the camera that permits manual or automatic switching between color and IR (black-and-white) operation. When IR mode is active,
Privacy Zones Masked areas of the dome camera's viewing area. These masks prevent operators of the surveillance system from viewing these design
Appendix D — Short Cut Key Short Cut Key Function PRST Pop up preset setup menu. TOUR Pop up guard Tour setup menu. PTRN Pop up Pattern setup m
39 SPECODOME CAMERA 040705
Table of Contents Chapter 1 — Introduction ...1 1.1 Features...
3.7 Tour ...15 3.8 Pattern ...
VII Dome Reset ...30 System Information ...
Chapter 1 — Introduction 1.1 Features The Fastrax II E dome camera and the Fastrax II Keyboard Controller make up the building blocks for any
UP TO 32 CAMERAUP TO 255 MULTIPLEXERUP TO 99 DVRJ-boxAlarm Input UP TO 8 Alarm Output UP TO 4<Sensor><Siren><Flashing Light>Master